FRP composite tanks are used in filtration, softening and related water treatment duties. A vessel that fits the floor plan can still be wrong for the media, valve connection or operating cycle. Review the full installation before confirming a model.
Start with the Stored Media and Liner
Hedelong's listed standard tank series uses a food-grade HDPE liner with epoxy resin and fiberglass winding reinforcement. Confirm what will contact the liner, including cleaning chemicals and any media used during regeneration. A material label alone does not establish compatibility for every concentration or temperature.
Compare the Operating Range
| Selection Item | Listed Standard Series | What to Verify |
|---|---|---|
| Diameter | 6–80 in | Model dimensions, height and installation clearance |
| Operating pressure | 125 psi and 150 psi options | Maximum pressure, cycling and the selected series rating |
| Operating temperature | 1–49°C (34–120°F) | Normal and cleaning temperatures for the actual medium |
| Openings | Threaded and flanged options | Connection size, standard and valve or distributor interface |
Values describe listed product ranges and are not universal ratings for every tank configuration.
Choose the Opening for the Maintenance Routine
Standard tanks, top-opening vessels and side-loading configurations serve different maintenance needs. Product information lists a 40 mm head opening on the top-opening series. A loading and unloading series uses upper and lower flanges and a separate media access port. Check which components need to be removed during media changes and whether there is room to do that in the installed position.
Confirm the Support and Documents
Share the base style, support surface, valve assembly, drawing and required certificates with the supplier. The standard series lists more than 100,000 pressure cycles in a 0–150 psi test and a burst test at four times design pressure. Ask for the report that applies to the model under quotation rather than assuming every size shares the same test record.
Compare the available FRP tank configurations and include the stored medium, pressure, temperature, opening style and delivery requirements in the request.